Calculate wire sizes, voltage drop, conduit fill, and other electrical values using NEC references. The endpoint needs no credentials.

How do I authenticate?

Add the endpoint directly in your client. The catalog records no authentication requirement; no OAuth sign-in or API key is configured in this setup. The live server may change.

Authentication and connection guide

Connection specification

Remote endpoint
https://sparkquote.ai/mcp
Browser access
Not yet measured
Declared MCP transport
Streamable HTTP
Live-validated MCP transport
Streamable HTTP — Observed by the latest catalog validation
Declared authentication
No authentication
Detected authentication
No authentication detected or retained from publisher evidence
Protocol lifecycle
Stateful MCP · 2025-11-25
Category
Reference

Product documentation · Official listing documentation · ChatGPT app directory listing

More Reference MCP servers · Browse all MCP servers · Test this endpoint in the MCP Playground

Authorization setup

No app registration needed

This catalog entry does not require authorization or provider app registration.

Connect it

Live-validated endpoint: https://sparkquote.ai/mcp · Streamable HTTP. No authentication is required by the catalog listing.

Agent prompt for Claude Code or Codex
Add the SparkQuote NEC Calculators MCP server to my MCP client configuration and verify that it works.

What it is: Calculate wire sizes, voltage drop, conduit fill, and other electrical values using NEC references. The endpoint needs no credentials.
Server URL: https://sparkquote.ai/mcp
Transport: Streamable HTTP (remote MCP server, no local install).
Authentication: none. The server accepts connections without credentials.
Tools (10, as last observed by mcptest): bid_calculator, box_fill, conduit_fill, load_calculator, nec_ampacity, ohms_law, panel_schedule, voltage_drop, watts_to_amps, wire_size.
Reference: https://mcptest.io/servers/sparkquote-nec-calculators/

Steps:
1. Work out which MCP client I use (Claude Code, Codex, Cursor, VS Code or another) and add the server under the name "sparkquote-nec-calculators" in that client's MCP configuration, user scope unless I ask otherwise.
   Claude Code: claude mcp add --transport http --scope user 'sparkquote-nec-calculators' 'https://sparkquote.ai/mcp'
   Codex: codex mcp add 'sparkquote-nec-calculators' --url 'https://sparkquote.ai/mcp'
   Other clients: use the setup for that client on the reference page.
2. Never write a credential value into a file that could be committed; reference an environment variable or the client's secret store, and ask me for any value you need.
3. Verify: connect to the server and call tools/list. Confirm the tools above are listed, and report any sign-in step I still have to complete.
MCP client

Claude Code setup

Run in a terminal. This user-scoped entry is available across projects.

claude mcp add --transport http --scope user 'sparkquote-nec-calculators' 'https://sparkquote.ai/mcp'

Codex CLI setup

Run in a terminal; Codex stores the entry in ~/.codex/config.toml.

codex mcp add 'sparkquote-nec-calculators' --url 'https://sparkquote.ai/mcp'

Cursor setup

Add to .cursor/mcp.json for this project, or ~/.cursor/mcp.json for all projects.

{
  "mcpServers": {
    "sparkquote-nec-calculators": {
      "url": "https://sparkquote.ai/mcp"
    }
  }
}

VS Code setup

Add to .vscode/mcp.json, or run “MCP: Open User Configuration” for a private user-level entry.

{
  "servers": {
    "sparkquote-nec-calculators": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}

Claude setup

Add the endpoint above in Claude:

  • Customize > Connectors > Add custom connector
  • Team/Enterprise: Organization settings > Connectors > Add > Custom > Web

Claude Desktop setup

Add the endpoint above in Claude Desktop:

  • Remote: Customize > Connectors (same as claude.ai)
  • Local: Settings > Developer > Edit Config, or Settings > Extensions for .mcpb files
  • ~/Library/Application Support/Claude/claude_desktop_config.json (macOS) or %APPDATA%\Claude\claude_desktop_config.json (Windows), local servers only

ChatGPT setup

Add the endpoint above in ChatGPT:

  • ChatGPT web: Plugins > Add custom MCP server, then configure authentication and accept the risk warning

Windsurf setup

Add the endpoint above in Windsurf:

  • ~/.config/devin/mcp_config.json (%APPDATA%\devin\mcp_config.json on Windows), serverUrl or url
  • Cascade panel > ... > MCPs > Open MCP config file

Gemini CLI setup

Add the endpoint above in Gemini CLI:

  • gemini mcp add --transport http <name> <url>
  • ~/.gemini/settings.json (user) or .gemini/settings.json (project), mcpServers

MCP SDK setup

Add the endpoint above in MCP SDK:

  • Programmatic: new Client(...).connect(new StreamableHTTPClientTransport(url))

Client compatibility

ClientStatusWhy
Claude CodeSupportedClaude Code supports Streamable HTTP servers and servers without authentication.
CodexPartialCodex's documentation does not state support for servers without authentication.
CursorSupportedCursor supports Streamable HTTP servers and servers without authentication.
VS CodeSupportedVS Code supports Streamable HTTP servers and servers without authentication.
ClaudeSupportedClaude supports Streamable HTTP servers and servers without authentication.
Claude DesktopSupportedClaude Desktop supports Streamable HTTP servers and servers without authentication.
ChatGPTPartialStateful routing needs operational care: ChatGPT can preserve MCP sessions, but the deployment must route a session consistently and retain its state.
WindsurfPartialWindsurf's documentation does not state support for servers without authentication.
Gemini CLISupportedGemini CLI supports Streamable HTTP servers and servers without authentication.
MCP SDKSupportedMCP SDK supports Streamable HTTP servers and servers without authentication.

Computed from this server's validated transport, protocol and authentication against documented client support. Checks the catalog has not observed are not counted.

Similar servers

  • FlickDirect Connect: Movie MCP Server — Read-only movie MCP server for FlickDirect movie and TV facts, available country dates and ratings, site-wide news and review previews, podcasts, streaming and deals. Free access with no authentication. No authentication
  • getAbstract — Search getAbstract summaries of business books, articles and reports. OAuth 2.1
  • The Old Ways Library — Public, read-only search and cited passages from historical editions and mythology reference pages across five traditions. No account or API key required. No authentication
  • Folklore Clinical Variant Interpretation MCP — Offers 11 public tools for ACMG/AMP germline variant classification, gene profiles, disease associations and literature. An optional Folklore Bearer API key adds 18 tools for case analysis, approved source files and reports. No authentication
  • MaCalculatrice (macalc) — Calculators from macalculatriceenligne.com as MCP tools: tax, salary, real estate, maths, health and unit conversions for France and other French-speaking countries. Each result links to the related page of the site. No authentication. No authentication
  • 链小知区块链 — Eight read-only tools for Chinese-language blockchain knowledge, tool guides, recent news (seven-day search window), event timelines and daily briefs, with source links. Anonymous Streamable HTTP; no API key or authentication. No authentication

Guides for this server

Watch this server for breaking changes

Share and embed

Maintain SparkQuote NEC Calculators? Embed this badge in your README. It follows the latest catalog validation result and links to this server profile.

mcptest.io: ready

Latest validation evidence

Validation status
Online when last tested
Validation checked at
Nov 23, 2026 at 7:19 PM
Validation detail
Negotiated stateful MCP 2025-11-25 at https://sparkquote.ai/mcp; detected transport streamable-http; authentication none

Tool inventory

What the catalog validator observed on at https://sparkquote.ai/mcp without credentials. The live server may have changed since; connect in the Playground for the current list.

Tools provided by SparkQuote NEC Calculators 10

  • bid_calculatoroutputSchema declared

    Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

    Input direct?: number, hours: number, margin: number, markup?: number, materials: number, overhead: number, rate: number
    • direct?: numberoptional

      Permits and other job costs ($). Optional.

    • hours: numberrequired

      Labor hours (h).

    • margin: numberrequired

      Target net margin (%).

    • markup?: numberoptional

      Material markup (%). Optional.

    • materials: numberrequired

      Material cost ($).

    • overhead: numberrequired

      Overhead (% of direct cost) (%).

    • rate: numberrequired

      Burdened labor cost ($/h).

  • box_filloutputSchema declared

    Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.

    Input awg: string, boxVolume?: number, clamps: string, conductors: number, devices: number, grounds: number, supports?: number
    • awg: stringrequired

      Largest conductor. "6" = 6 AWG; "8" = 8 AWG; "10" = 10 AWG; "12" = 12 AWG; "14" = 14 AWG; "16" = 16 AWG; "18" = 18 AWG.

    • boxVolume?: numberoptional

      Marked box volume (blank for minimum only) (in³). Optional.

    • clamps: stringrequired

      Internal cable clamps. "0" = None; "1" = One or more.

    • conductors: numberrequired

      Insulated conductors (not counting grounds).

    • devices: numberrequired

      Devices (switches, receptacles).

    • grounds: numberrequired

      Equipment grounds entering box (count).

    • supports?: numberoptional

      Support fitting types (stud / hickey). Optional.

  • conduit_filloutputSchema declared

    Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

    Input awg: string, count: number, groups?: string, size: string, type: string
    • awg: stringrequired

      THHN/THWN-2 size. "1" = 1 AWG; "2" = 2 AWG; "3" = 3 AWG; "4" = 4 AWG; "6" = 6 AWG; "8" = 8 AWG; "10" = 10 AWG; "12" = 12 AWG; "14" = 14 AWG; "1/0" = 1/0 AWG; "2/0" = 2/0 AWG; "3/0" = 3/0 AWG; "4/0" = 4/0 AWG.

    • count: numberrequired

      Number of conductors.

    • groups?: stringoptional

      Mixed THHN/THWN-2 groups: quantity, size per line (blank uses the single-size inputs)

    • size: stringrequired

      Trade size. "1" = 1"; "2" = 2"; "3" = 3"; "4" = 4"; "1/2" = 1/2"; "3/4" = 3/4"; "1-1/4" = 1-1/4"; "1-1/2" = 1-1/2"; "2-1/2" = 2-1/2"; "3-1/2" = 3-1/2".

    • type: stringrequired

      Conduit type. "EMT" = EMT; "PVC-40" = PVC Schedule 40.

  • load_calculatoroutputSchema declared

    Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.

    Input dishwasher?: number, disposal?: number, dryer?: number, ev?: number, heater?: number, hvac?: number, laundry: string, other?: number, range?: number, small: number, sqft: number
    • dishwasher?: numberoptional

      Dishwasher (VA). Optional.

    • disposal?: numberoptional

      Disposal (VA). Optional.

    • dryer?: numberoptional

      Dryer (VA). Optional.

    • ev?: numberoptional

      EV charger (VA). Optional.

    • heater?: numberoptional

      Water heater (VA). Optional.

    • hvac?: numberoptional

      Largest of heating or cooling (VA). Optional.

    • laundry: stringrequired

      Laundry circuit. "1" = Yes (1,500 VA); "0" = No.

    • other?: numberoptional

      Other fixed appliances (VA). Optional.

    • range?: numberoptional

      Range / cooktop (VA). Optional.

    • small: numberrequired

      Small-appliance circuits.

    • sqft: numberrequired

      Living area (ft²).

  • nec_ampacityoutputSchema declared

    Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.

    Input material: string, size: string, temp: string
    • material: stringrequired

      "cu" = copper; "al" = aluminum.

    • size: stringrequired

      Conductor size: AWG ("14" … "4/0") or kcmil ("250" … "500").

    • temp: stringrequired

      Temperature column in °C: 60 (NM-B, UF), 75 (THWN, most terminations), 90 (THHN, for derating).

  • ohms_lawoutputSchema declared

    Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

    Input i?: number, p?: number, r?: number, v?: number
    • i?: numberoptional

      Current (A). Optional.

    • p?: numberoptional

      Power (W). Optional.

    • r?: numberoptional

      Resistance (Ω). Optional.

    • v?: numberoptional

      Voltage (V). Optional.

  • panel_scheduleoutputSchema declared

    Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

    Input circuits: string, spaces: string, system: string
    • circuits: stringrequired

      Circuits: description, breaker A, poles, VA (one per line)

    • spaces: stringrequired

      Spaces. "12" = 12; "20" = 20; "24" = 24; "30" = 30; "42" = 42.

    • system: stringrequired

      Panel. "1" = 120/240 V single-phase; "3" = 208Y/120 V three-phase.

  • voltage_dropoutputSchema declared

    Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

    Input amps: number, awg: string, feet: number, material: string, phase: string, volts: string
    • amps: numberrequired

      Load current (A).

    • awg: stringrequired

      Size. "14" = 14 AWG; "12" = 12 AWG; "10" = 10 AWG; "8" = 8 AWG; "6" = 6 AWG; "4" = 4 AWG; "3" = 3 AWG; "2" = 2 AWG; "1" = 1 AWG; "1/0" = 1/0 AWG; "2/0" = 2/0 AWG; "3/0" = 3/0 AWG; "4/0" = 4/0 AWG; "250" = 250 kcmil; "300" = 300 kcmil; "350" = 350 kcmil; "400" = 400 kcmil; "500" = 500 kcmil.

    • feet: numberrequired

      One-way distance (ft).

    • material: stringrequired

      Conductor. "cu" = Copper; "al" = Aluminum.

    • phase: stringrequired

      Phase. "1" = Single-phase; "3" = Three-phase.

    • volts: stringrequired

      Voltage. "120" = 120 V; "208" = 208 V; "240" = 240 V; "277" = 277 V; "480" = 480 V.

  • watts_to_ampsoutputSchema declared

    Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

    Input pf: number, phase: string, volts: string, watts: number
    • pf: numberrequired

      Power factor.

    • phase: stringrequired

      Phase. "1" = Single-phase; "3" = Three-phase.

    • volts: stringrequired

      Voltage. "120" = 120 V; "208" = 208 V; "240" = 240 V; "277" = 277 V; "480" = 480 V.

    • watts: numberrequired

      Power (W).

  • wire_sizeoutputSchema declared

    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

    Input amps: number, feet: number, limit: number, material: string, phase: string, temp: string, volts: string
    • amps: numberrequired

      Breaker / load (A).

    • feet: numberrequired

      One-way distance (ft).

    • limit: numberrequired

      Max voltage drop (%).

    • material: stringrequired

      Conductor. "cu" = Copper; "al" = Aluminum.

    • phase: stringrequired

      Phase. "1" = Single-phase; "3" = Three-phase.

    • temp: stringrequired

      Termination rating. "60" = 60°C (NM-B, UF); "75" = 75°C (THHN in conduit); "90" = 90°C.

    • volts: stringrequired

      Voltage. "120" = 120 V; "208" = 208 V; "240" = 240 V; "277" = 277 V; "480" = 480 V.